%A0; Overview

With batteries used for electronic tools requiring greater capacity in recent years, secondary lithium ion batteries are being used more often.
There are currently 3 to 5 cells within a battery, and the 3-cell battery specifications (10.8V) that make up the majority of the market have a greater need for temperature protection and multi-step overcurrent protection.
Using the enables a lower cost and higher level of safety than could be achieved using existing circuits.

§ Features

1.

Overcharge, overdischarge and overcurrent protection functions built-in.

2.

Monitor and protect against discharge overcurrent with 3 steps (overcurrent 1, overcurrent 2, short circuit protection)

3.

Detection of high and low temperatures with 3 values with an external NTC thermistor to protect the battery pack.

4.

Charging prohibited/permitted can be selected for 0V battery (optional)


§ Main specifications

Overcharge detection

3.6 to 4.5V (5mV steps) accuracy ±25mV

Overcurrent detection

2.0 to 3.0V (50mV steps) accuracy ±80mV

Discharge overcurrent detection voltage 1

30 to 300mV (5mV steps) accuracy ±15%/±10mV

Discharge overcurrent detection voltage 2

2x/4x discharge overcurrent 1 accuracy ±20%

Short circuit detection voltage

4x/8x discharge overcurrent 1 accuracy ±30%

Discharge overcurrent detection voltage

-300 to -20mV (5mV steps) accuracy ±15%/±10mV

Temperature protection detection temperature

-30℃ to 80℃ (5℃ steps, 3 values can be set) accuracy ±3℃

REG terminal output voltage

1.5 to 3.0V (50mV steps) accuracy ±25mV

Package

TSOP-16B

Dimensions

5.0×4.4×1.1mm (W×D×H)